About InveStore v4
       About InveStore v4
       Graphical User Interface Features
       Administrator "Views"
       Product Specifications
       Minimum System Requirements
       File Systems
       Volume Management
       Compatibility
       Standard Features
       Terminology
       Keyboard and Mouse Conventions
Installing and Starting the Software
       Installing and Starting The Software
       Installation steps
       System Startup
       System Shutdown
       InveStore Enterprise
       Attaching a Drive Letter
       Software Registration and Activation
       Re-activation Requests
       Running InveStore as a Windows Service
       Windows Net Stop and Net Start commands
       Updating the Windows Workstation Registry
Navigating the Console
       Navigating The Management Console
       Action Icons
       InveStore Enterprise
       Enterprise Properties
       InveStore Server Node
       Server Tools
       General Server Information
       Settings Management
       Cache Management
       Performance Management
       Backup Management
       InveStore Event Logs
       Volume Sets Node
       Libraries
Managing the Storage Subsystem
       Understanding Storage Libraries
       Handling Volumes
       The InveStore Console Nodes
       Enterprise Node
       Enterprise "Right Click" functions
       Enterprise Properties
       Storage Server Node
       Server Tools
       General Server Information
       Settings Management
       Cache
       Performance
       Backup
       InveStore Event Logs
       How Read the Event Log Files
       Error Codes in the InveStore log files
       SCSI Request Sense Key
       Volume Sets Node
       Volume Set Specification
       Intelligent Spanning
       Volume Sets (root) Right Mouse Click Options
       Volume Sets (root) Properties
       Individual Volume Set (Individual) Properties
       Volume Properties (Surface)
       Libraries Node
       Libraries Properties (root)
       Library Properties (Individual)
       Drive "Right Click" Options
       Drive Properties
       Drive Settings
       Formatting a Volume Set
       Considerations for Creating Volume Sets
       Media Used
       Formatting Bar Code Media
       Format Volume Set: Step 1
       Format Volume Set: Step 2
       Reserved Volume Naming Conventions
       Un-mounting a Volume
       Mounting or Pre-mounting a storage volume
       Other Mount Options
       Forced Mount
       Mounting Bar Code Media
       Remount
       Committing a Volume Set
       Renaming a Volume
Volume Sets
       Volume Set Specification
       Intelligent Spanning
       Reserved Volume Naming Conventions
       Volume Sets
       Volume Sets (root) Right Mouse Click Options
       Volume Sets (root) Properties
       Individual volume set Properties
       Volume Properties (surface)
       Formatting a Volume Set
       Considerations for Creating Volume Sets
       Media Used
       Formatting Bar Code Media
       Format Volume Set: Step 1
       Format Volume Set: Step 2
       Reserved Volume Naming Conventions
       Mounting or Pre-mounting a storage volume
       Other Mount Options
       Forced Mount
       Mounting Bar Code Media
       Remount
       Un-mounting a Volume
       Extending a Volume Set
       Reinitialize
       Recycle
       Erase
       Commit
       Set Reserved Space
       Set Watermarks
       Rename
Sharing the InveStore Resource
       Sharing InveStore on a Windows Network
       Mapping to a Windows 9x or NT/2000/2003/XP Client
       Sharing the InveStore resource via the Internet
Backing up a Volume Set
       Backing Up An Storage Volume
       Configuring Volume Backup
       Backup Schedule
       Status
Optimizing System Performance
       Optimizing System Performance
       Server Tools
       Settings Management
       Cache Management
       Default Write Algorithm
       Lazy Write
       Write Through
       Flush on Close
       Default Write Algorithm Recommendations
       Performance Management
       Improving the Performance of your Storage Server
Server Setup and Subsystem Issues
       Server Sub-System & SCSI Setup Issues
       SCSI Adapter Boards
       System RAM and Pagefile Settings
       Uninterruptible Power Supply (UPS)
       SCSI BUS Lengths
       Calculating the true SCSI Bus Length
       SCSI Bus Termination and Cables
       Daisy-chaining SCSI Devices
       SCSI Addressing Requirements
       SCSI Bus Addressing Issues
       Target Mode setup for HP
       Console Opens, but Nothing is Displayed Under Enterprise Node
       InveStore Functions Not Allowed
       Disable Devices
       InveStore Service Setup after Uninstall
       Windows 2000 (SP4) Service Setup after Uninstall
       Windows 2003 Service Setup after Uninstall
       Windows XP (SP2) Service Setup after Uninstall
Common Errors and Problems
       Console Opens, but Nothing Shows Under Enterprise View
       Kernel Initialization Failed
       InveStore Functions Not Allowed
       Error attempting InveStore functions from remote site using Windows Terminal Services
       Errors seen with earlier version of InveStore, after installing v4
       System hangs during READ / WRITE operations immediately after upgrade to InveStore v4 or gr
       Error Occurred While trying to Share PDTOFS
       COM/DCOM Requirements under Windows
       Manually adding the Drive Letter in the Registry
       Manually Registering InveStore MMC
       Standard Recovery
       InveStore appears to start, but shows no activity
       ASPI and SCSI Errors
       SCSI/ASPI Disconnect Issues
       SCSI Specification
       SCSI Cable Length
       Calculating the true SCSI Bus Length
       SCSI Bus Addressing Issues
       Bus Reset
       SCSI Analyzer
       Adding a Second Drive in an existing Library
       Drive Letter Assignment Problem
       Removing CD Claim from Windows Registry
       Windows Operating System Blue Screen
       Daisy Chain
       DASD - Hard Drive Requirements for InveStore
       The Importance of Defragmenting your Hard Drive
       Disabling CD/DVD Autorun under Windows
       Drive Spin Up, Move Media and Drive not Ready
       Media Backward Compatibility
       Multiple Library Limitations
       Seeing multiple libraries for one library
       No Supported Host Adapter Found
       No Supported Devices Found
       Mounted volumes not showing in Explorer
       Non-Approved SCSI Adapters
       Error attempting to obtain drive access, OFFLINE drives, or no drives available
       Attempt to place a disk into an occupied slot
       Why is the system loading each disk at startup?
       Unsupported SCSI Device Found
       The Benefits of Using CHKDSK
       HP C1113M 9.1 GB drives
       The ordinal 6688 could not be located in the dynamic link library MFC42.DLL
       Moving a volume from one Library to another
       HCM and Multiple-drive Write Operations
       Choosing a SCSI Host Adapter
Trouble Shooting and Support
       Troubleshooting & Technical Support
       The InveStore Event Log File
       Standard Operations in Event Log
       Opening an Event Log
       How Read the Event Log Files
       Error Codes in the InveStore log files
       SCSI Request Sense Key Data
       Console Opens, but Nothing Shows Under Enterprise View
       Initialize Element Status
       Scan Elements
       Testing Your InveStore Storage System
       Cannot format media mounted as "!unknown volume". Receive error that it is "not accessible
       WNASPI32.DLL not found
       No supported SCSI device found.
       During system boot, the computer hangs
       Insufficient Magnetic Disk Space -- Disk is Full (errors 0x00c6, 0x00c9)
       Volume in Slot is NOT Pegasus Format and cannot be Ref-erenced (error 0x00af)
       Drive Not Ready
       Access Denied
       Insufficient Memory (PageFile drive space)
       Magnetic File Open Failure
       Invalid System Parameter
       Error Removing Media
       Volume Not Mounted, or Error Mounting Media
       InveStore Registry Editor
       Disable Devices
       Receiving Technical Support
       Pegasus Technical Support Contact Information
Device Specific Issues
       Device Specific Issues
       SCSI Bus Addressing Issues
       Hewlett Packard (AA968A) mixed media library (UDO & M.O.)
       Plasmon Bar Code Storage Library
       Plasmon "Standard" D Series DVD-RAM Library
       Plasmon Enterprise D Series DVD-RAM Library
       Setup and Configuration of 3 Bus Plasmon Library
       DISC NSM4000
       Panasonic DVD-RAM Drives and Media
       DISC D-20 and D-40 (OEM Maxoptix)
       Asaka
       ASM Setup
       Pioneer DRM-1004x CD Library
       SONY CDL2200 Library
       LMSI
       LMSI Diagnostics
       PowerFile C200 & R200 DVD Changers
       PowerFile Operations
       Using PowerFile Service Mode to Manually Remove Discs
       PowerFile "Illegal SCSI CDB Value"
       Setup Issue with PowerFile device in the Windows Operating System
       Installing a PowerFile in Windows XP
       Loading Drivers for the PowerFile C200 under Windows 2000
       PowerFile Technical Support Contact Information
Hex Error Code Directory
       InveStore Event Log HEX Error Codes
       General Errors
       Memory Manager Errors
       Btree Errors
       File Allocation Descriptor (FAD) BTREE Errors
       PFM error codes
       Mount Error
       OHIM Errors
       DLL Errors
       Basic Disk Errors
       Asynchronous Timer Errors
       Thread/Process Errors
       Semaphore Manager Errors
       HCM Errors
       Interprocess Communications Errors
       File Errors
       Shared Memory Errors